SMART-P Panel type

Explanation
Specially developed for devices and machines that control limit values ​​through weight measurements, SMART-P is a small and simple weight indicator with a durable and robust housing. It is a reliable and economical solution for electronic detection and protection against overloads of cranes and elevators.

Features
• Impact-resistant plastic case
• 4-digit red LED weight display
• Dust- and moisture-resistant membrane keyboard with tactile keys
• Calibration, reset, function and setting keys
• Zeroing over the entire measuring range
• Gain setting for load cell output
• RS232/RS485 serial outputs
• Internal relay output
• Analog output (4-20 mA)
• Analog output (0-5 V)

Accuracy
Accuracy class (OIML approved) 1000 (III)
Input Sensitivity 0.5µV/digit
Sensitivity 0.015%
Null and gain stability 5ppm/°C
A/D converter 16bit
Digital filter Numeric filtering
Read Frequency 10Hz
Strain gauges
Number of strain gauges allowed datsichi 4 pieces (350ohm)
Analog Input Range ± 2mV/V
Supply voltage 5V DC
Environment
Operating Temperature Range (OIML) -10°C +40°C
Storage temperature range -20°C +70°C
Operating voltage and power 10-35V DC – 5W
Operator and Display Operation
Keyboard Dust and moisture resistant membrane keyboard with 3 tactile keys
Weight Display 6mm, 4-digit, 7-segment LED display
Function display LED zero indicators, no movement
Program indicator –
Box
Material and Protection Class Plastic, IP65
Weight 0.2kg
Package weight and dimensions 0.3kg, 15x24x6cm
Communication Standard                                        Optional
Serial communication output RS232/RS485                                            –
Output for parallel printer –
Binary (BCD) output –
Remote Display Output –
Digital Inputs / Outputs 1 input / 3 outputs (2A relay)                  –
Analog output 4-20mA / 0-5V                                            –
BCD and digital I/O cannot be used at the same time.   Areas of application Overload control systems
This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.