{"id":2815,"date":"2025-07-13T17:22:01","date_gmt":"2025-07-13T14:22:01","guid":{"rendered":"https:\/\/development.pirosmani.restaurant\/shop\/uncategorized\/plc-tenzometrichen-datchik\/"},"modified":"2025-09-10T04:55:39","modified_gmt":"2025-09-10T01:55:39","slug":"plc-tenzometrichen-datchik","status":"publish","type":"product","link":"https:\/\/development.pirosmani.restaurant\/en\/shop\/strain-gauges\/plc-tenzometrichen-datchik\/","title":{"rendered":"PLC Strain gauge"},"content":{"rendered":"<p data-start=\"0\" data-end=\"41\"><strong data-start=\"0\" data-end=\"41\">2 t &#8211; 5 t &#8211; 10 t &#8211; 20 t &#8211; 30 t &#8211; 60 t<\/strong><\/p>\n<p data-start=\"43\" data-end=\"282\"><br data-start=\"58\" data-end=\"61\" \/><strong data-start=\"61\" data-end=\"75\">Explanation:<\/strong><br data-start=\"75\" data-end=\"78\" \/>PLC pin type strain gauges are specially designed for crane systems. They are mounted on the balance roller of the crane&#8217;s lifting mechanism and take into account the load exerted on the roller.<\/p>\n<p data-start=\"284\" data-end=\"523\">With its steel alloy construction coated with corrosion-resistant paint, as well as the strain gauge area welded with a stainless steel cover, the PLC is protected according to the IP68 standard, which means full water resistance.<\/p>\n<p data-start=\"525\" data-end=\"564\">PLC strain gauges provide:<\/p>\n<p data-start=\"566\" data-end=\"664\">Overload control for cranes and lifting machines<br data-start=\"619\" data-end=\"622\" \/>Measuring the weight of the load being lifted<\/p>\n<p data-start=\"666\" data-end=\"685\"><strong data-start=\"666\" data-end=\"685\">Features:<\/strong><\/p>\n<p data-start=\"687\" data-end=\"715\">\u00e2\u20ac\u00a2 Industrial protection IP68<\/p>\n<p data-start=\"717\" data-end=\"731\"><strong data-start=\"717\" data-end=\"731\">Accessories:<\/strong><\/p>\n<p data-start=\"733\" data-end=\"758\" data-is-last-node=\"\" data-is-only-node=\"\">\u00e2\u20ac\u00a2 Junction Box (J Box)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Technical characteristics:<\/p>\n<p>Specifications<\/p>\n<table>\n<thead>\n<tr>\n<td width=\"299\"><strong>Parameter<\/strong><\/td>\n<td width=\"55\"><strong>Unit<\/strong><\/td>\n<td width=\"242\"><strong>Value<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td width=\"299\">Maximum capacity (Emax)<\/td>\n<td width=\"55\">kg<\/td>\n<td width=\"242\">2000, 5000, 10000, 15000, 20000, 30000, 60000<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Accuracy (OIML R60)<\/td>\n<td width=\"55\"><\/td>\n<td width=\"242\"><\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Maximum number of check intervals<\/td>\n<td width=\"55\"><\/td>\n<td width=\"242\"><\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Minimum check interval<\/td>\n<td width=\"55\"><\/td>\n<td width=\"242\"><\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Combined error<\/td>\n<td width=\"55\">%<\/td>\n<td width=\"242\">\u00e2\u2030\u00a4 \u00c2\u00b11.0<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Crawl Error (30 min) (DR)<\/td>\n<td width=\"55\">%Emax<\/td>\n<td width=\"242\"><\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Maximum safe overload<\/td>\n<td width=\"55\">%Emax<\/td>\n<td width=\"242\">150<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Maximum Safe Lateral Load<\/td>\n<td width=\"55\">%Emax<\/td>\n<td width=\"242\">300<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">End Load<\/td>\n<td width=\"55\">%Emax<\/td>\n<td width=\"242\"><\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Stretch (Emax)<\/td>\n<td width=\"55\">mm<\/td>\n<td width=\"242\"><\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Maximum supply voltage (Umax)<\/td>\n<td width=\"55\">V<\/td>\n<td width=\"242\"><\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Supply Current<\/td>\n<td width=\"55\">mA<\/td>\n<td width=\"242\">10<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Output signal (at rated load)<\/td>\n<td width=\"55\">Say\u00c4\u00b1m<\/td>\n<td width=\"242\">1mV\/V<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Analog to Digital Converter (Sigma Delta)<\/td>\n<td width=\"55\">bit<\/td>\n<td width=\"242\">\u00e2\u2030\u00a4 \u00c2\u00b15.0<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">A\/D converter speed<\/td>\n<td width=\"55\">Hz<\/td>\n<td width=\"242\">730 \u00c2\u00b120<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Asynchronous communication speed<\/td>\n<td width=\"55\">Baud<\/td>\n<td width=\"242\">700 \u00c2\u00b120<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Data interface<\/td>\n<td width=\"55\"><\/td>\n<td width=\"242\">\u00e2\u2030\u00a5500<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Angle measurement error<\/td>\n<td width=\"55\">degree<\/td>\n<td width=\"242\">-10&#8230;+40<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Insulation Voltage<\/td>\n<td width=\"55\">V<\/td>\n<td width=\"242\">-40&#8230;+80<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Temperature compensation range<\/td>\n<td width=\"55\">\u00c2\u00b0C<\/td>\n<td width=\"242\">Steel<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Operating temperature range<\/td>\n<td width=\"55\">\u00c2\u00b0C<\/td>\n<td width=\"242\">IP68<\/td>\n<\/tr>\n<tr>\n<td width=\"299\"> Strain gauge material<\/td>\n<td width=\"55\"><\/td>\n<td width=\"242\">5\u00c2\u00b1%3<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Sealing (EN60529)<\/td>\n<td width=\"55\"><\/td>\n<td width=\"242\">5<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Weight<\/td>\n<td width=\"55\"> kg<\/td>\n<td width=\"242\">\n<table width=\"100%\">\n<tbody>\n<tr>\n<td width=\"19%\">0.9 kg<\/td>\n<td width=\"15%\">1.1 kg<\/td>\n<td width=\"18%\">2.5 kg<\/td>\n<td width=\"14%\">4.1 kg<\/td>\n<td width=\"12%\">8.5 kg<\/td>\n<td width=\"12%\">11.7 kg<\/td>\n<td width=\"30%\">12.7 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"299\">Package Dimensions \/ Weight<\/td>\n<td width=\"55\">cm\/kg<\/td>\n<td width=\"242\">\n<table width=\"100%\">\n<tbody>\n<tr>\n<td width=\"19%\">1.2 kg<\/td>\n<td width=\"15%\">1.4 kg<\/td>\n<td width=\"17%\">2.8 kg<\/td>\n<td width=\"13%\">4.4 kg<\/td>\n<td width=\"12%\">8.8 kg<\/td>\n<td width=\"13%\">12 kg<\/td>\n<td width=\"33%\">13 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>Field of application<\/p>\n<p>Overload control systems<\/p>\n","protected":false},"featured_media":2297,"template":"","meta":[],"product_brand":[],"product_cat":[247],"product_tag":[],"class_list":["post-2815","product","type-product","status-publish","has-post-thumbnail","product_cat-strain-gauges","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/development.pirosmani.restaurant\/en\/wp-json\/wp\/v2\/product\/2815","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/development.pirosmani.restaurant\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/development.pirosmani.restaurant\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/development.pirosmani.restaurant\/en\/wp-json\/wp\/v2\/media\/2297"}],"wp:attachment":[{"href":"https:\/\/development.pirosmani.restaurant\/en\/wp-json\/wp\/v2\/media?parent=2815"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/development.pirosmani.restaurant\/en\/wp-json\/wp\/v2\/product_brand?post=2815"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/development.pirosmani.restaurant\/en\/wp-json\/wp\/v2\/product_cat?post=2815"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/development.pirosmani.restaurant\/en\/wp-json\/wp\/v2\/product_tag?post=2815"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}